Correlative Postural Gait Descriptor to Discriminate Parkinsonian Findings in a Markerless Analysis

Keywords: correlation matrices, covariance matrices, gait analysis, motion capture, Parkinson disease

Abstract

Parkinson's disease (PD) is one of the most prevalent neurodegenerative disorders worldwide, with over 10 million cases reported globally. Currently, gait analysis is crucial for quantifying motor abnormalities, and most methods rely on physical markers, which alter patients' natural movements and have limitations in explaining spatiotemporal relationships of the joints. This study aimed to implement a markerless methodology that reconstructs gait postures and encodes spatiotemporal joint information as covariance descriptors, which are then used to discriminate between subjects with Parkinson's disease and healthy controls. The methodology consisted of a study of covariance encoding of postures and joint trajectories to identify potential coordination patterns that aid in PD classification. The results obtained in a population of 30 subjects, recorded in a total of 240 videos, approved by the Scientific Research Ethics Committee of Universidad Industrial de Santander (CEINCI), showed an average PD classification accuracy of 75% and an AUC of 74%. In conclusion, the correlation descriptors demonstrated the potential to discriminate between subjects with PD and healthy controls and to encode coordination patterns. Furthermore, the visual correlation maps show differences between the two groups, which can further support routine clinical analysis.

Author Biographies

Jean Portilla, Universidad Industrial de Santander

Bucaramanga, Colombia, jean2248075@correo.uis.edu.co

Edgar Rangel Pieschacon, Universidad Industrial de Santander

Bucaramanga, Colombia, edgar.rangel@correo.uis.edu.co

Odair Bacca, Universidad Industrial de Santander

Bucaramanga, Colombia, oabaccar@uis.edu.co

Paula C. Ramírez, Universidad Industrial de Santander

Bucaramanga, Colombia, pcramire@uis.edu.co

Luis Guayacán, Universidad Industrial de Santander

Bucaramanga, Colombia, luis.guayacan@saber.uis.edu.co

Fabio Martínez Carrillo, Universidad Industrial de Santander

Bucaramanga, Colombia, famarcar@saber.uis.edu.co

References

GBD 2017 US Neurological Disorders Collaborators, “Burden of Neurological Disorders Across the US From 1990-2017: A Global Burden of Disease Study,” JAMA Neurol., vol. 78, no. 2, pp. 165-176, Feb. 2021. https://doi.org/10.1001/jamaneurol.2020.4152

A. Zhao, E. Cui, A. Leroux, M. A. Lindquist, and C. M. Crainiceanu, “Evaluating the prediction performance of objective physical activity measures for incident Parkinson’s disease in the UK Biobank,” J. Neurol., vol. 270, no. 12, pp. 5913-5923, Aug. 2023. https://doi.org/10.1007/s00415-023-11939-0

E. Ray Dorsey, T. Sherer, M. S. Okun, and B. R. Bloem, “The Emerging Evidence of the Parkinson Pandemic,” J. Park. Dis., vol. 8, no. s1, pp. S3–S8, Dec. 2018. https://doi.org/10.3233/JPD-181474

E. Rovini, C. Maremmani, and F. Cavallo, “How Wearable Sensors Can Support Parkinson’s Disease Diagnosis and Treatment: A Systematic Review,” Front. Neurosci., vol. 11, Oct. 2017. https://doi.org/10.3389/fnins.2017.00555

R. Baker, “Gait analysis methods in rehabilitation,” J. NeuroEngineering Rehabil., vol. 3, no. 4, Mar. 2006. https://doi.org/10.1186/1743-0003-3-4

J. Kulisevsky et al., “Enfermedad de Parkinson avanzada. Características clínicas y tratamiento (parte I),” Neurología, vol. 28, no. 8, pp. 503-521, Oct. 2013. https://doi.org/10.1016/j.nrl.2013.05.001

W. Poewe et al., “Parkinson disease,” Nat. Rev. Dis. Primer, vol. 3, no. 1, pp. 1-21, Mar. 2017. https://doi.org/10.1038/nrdp.2017.13

K. Berganzo et al., “Motor and non-motor symptoms of Parkinson’s disease and their impact on quality of life and on different clinical subgroups,” Neurol. Engl. Ed., vol. 31, no. 9, pp. 585-591, Nov.-Dec. 2016. https://doi.org/10.1016/j.nrleng.2014.10.016

C. León-Jiménez, “Síndrome rígido acinético,” Rev. Med. Clínica, vol. 3, no. 2, pp. 104-108, May. 2019. https://doi.org/10.5281/ZENODO.3236571

N. B. Ramírez, N. P. Álvarez, S. Q. Aguilar, and L. N. Orozco, “Datos clave para el diagnóstico clínico de enfermedad de Parkinson,” Rev. Mex. Neurocienc., vol. 10, no. 5, pp. 340-343, Sep.-Oct. 2009. https://www.medigraphic.com/cgi-bin/new/resumen.cgi?IDARTICULO=44661

S. Garrido-Elustondo, B. Reneses, A. Navalón, O. Martín, I. Ramos, and M. Fuentes, “Capacidad de detección de patología psiquiátrica por el médico de familia,” Aten. Primaria, vol. 48, no. 7, pp. 449-457, Aug.-Sep. 2016. https://doi.org/10.1016/j.aprim.2015.09.009

M. Iosa, P. Picerno, S. Paolucci, and G. Morone, “Wearable inertial sensors for human movement analysis,” Expert Rev. Med. Devices, vol. 13, no. 7, pp. 641-659, Jun. 2016. https://doi.org/10.1080/17434440.2016.1198694

The Lancet, “Artificial intelligence in health care: within touching distance,” Lancet Lond. Engl., vol. 390, no. 10114, p. 2739, Dec. 2017. https://doi.org/10.1016/S0140-6736(17)31540-4

R. Caldas, M. Mundt, W. Potthast, F. Buarque de Lima Neto, and B. Markert, “A systematic review of gait analysis methods based on inertial sensors and adaptive algorithms,” Gait Posture, vol. 57, pp. 204-210, Sep. 2017. https://doi.org/10.1016/j.gaitpost.2017.06.019

G. Pal, and C. G. Goetz, “Assessing Bradykinesia in Parkinsonian Disorders,” Front. Neurol., vol. 4, Jun. 2013. https://doi.org/10.3389/fneur.2013.00054

C.-Y. Hsu, Y.-S. Tsai, C.-S. Yau, H.-H. Shie, and C.-M. Wu, “Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System,” Sensors, vol. 16, no. 8, p. 1156, Aug. 2016. https://doi.org/10.3390/s16081156

E. Balaji, D. Brindha, and R. Balakrishnan, “Supervised machine learning based gait classification system for early detection and stage classification of Parkinson’s disease,” Appl. Soft Comput., vol. 94, p. 106494, Sep. 2020. https://doi.org/10.1016/j.asoc.2020.106494

A. I. Cuesta-Vargas, A. Galán-Mercant, and J. M. Williams, “The use of inertial sensors system for human motion analysis,” Phys. Ther. Rev., vol. 15, no. 6, pp. 462-473, Dec. 2010. https://doi.org/10.1179/1743288X11Y.0000000006

C. Wong, Z.-Q. Zhang, B. Lo, and G.-Z. Yang, “Wearable Sensing for Solid Biomechanics: A Review,” IEEE Sens. J., vol. 15, no. 5, pp. 2747-2760, May. 2015. https://doi.org/10.1109/JSEN.2015.2393883

C.-W. Cho, W.-H. Chao, S.-H. Lin, and Y.-Y. Chen, “A vision-based analysis system for gait recognition in patients with Parkinson’s disease,” Expert Syst. Appl., vol. 36, no. 3, Part 2, pp. 7033-7039, Apr. 2009. https://doi.org/10.1016/j.eswa.2008.08.076

O. Ťupa et al., “Motion tracking and gait feature estimation for recognising Parkinson’s disease using MS Kinect,” Biomed. Eng. OnLine, vol. 14, no. 97, Oct. 2015. https://doi.org/10.1186/s12938-015-0092-7

A. Viswakumar, V. Rajagopalan, T. Ray, and C. Parimi, “Human Gait Analysis Using OpenPose,” in 2019 Fifth Int. Conf. Image Inform. Process. (ICIIP), Shimla, India, 2019, pp. 310-314. https://doi.org/10.1109/ICIIP47207.2019.8985781

A. Rohan, M. Rabah, T. Hosny, and S.-H. Kim, “Human Pose Estimation-Based Real-Time Gait Analysis Using Convolutional Neural Network,” IEEE Access, vol. 8, pp. 191542-191550, 2020. https://doi.org/10.1109/ACCESS.2020.3030086

L. C. Guayacán, and F. Martínez, “Visualising and quantifying relevant parkinsonian gait patterns using 3D convolutional network,” J. Biomed. Inform., vol. 123, p. 103935, Nov. 2021. https://doi.org/10.1016/j.jbi.2021.103935

G. Varol, I. Laptev, and C. Schmid, “Long-Term Temporal Convolutions for Action Recognition,” IEEE Trans. Pattern Anal. Mach. Intell., vol. 40, no. 6, pp. 1510-1517, Jun. 2018. https://doi.org/10.1109/TPAMI.2017.2712608

Z. Cao, T. Simon, S.-E. Wei, and Y. Sheikh, “Realtime Multi-Person 2D Pose Estimation Using Part Affinity Fields,” in Proceed. IEEE Conf. Comput. Vision Pattern Recogn., 2017, pp. 7291-7299. https://doi.org/10.48550/arXiv.1611.08050

R. Bhidayasiri, and D. Tarsy, “Parkinson’s Disease: Hoehn and Yahr Scale,” in Movement Disorders: A Video Atlas: A Video Atlas, R. Bhidayasiri, and D. Tarsy, Eds., Totowa, NJ: Humana Press, 2012, pp. 4-5. https://doi.org/10.1007/978-1-60327-426-5_2

R. Moe-Nilssen, M. K. Aaslund, C. Hodt-Billington, and J. L. Helbostad, “Gait variability measures may represent different constructs,” Gait Posture, vol. 32, no. 1, pp. 98-101, May. 2010. https://doi.org/10.1016/j.gaitpost.2010.03.019

A. Kale, N. Cuntoor, B. Yegnanarayana, A. N. Rajagopalan, and R. Chellappa, “Gait Analysis for Human Identification,” in Audio- and Video-Based Biometric Person Authentication, J. Kittler, and M. S. Nixon, Eds., Berlin, Heidelberg: Springer, 2003, pp. 706-714. https://doi.org/10.1007/3-540-44887-X_82

Y. Liu, Y. Wang, and J. Zhang, “New Machine Learning Algorithm: Random Forest,” en Information Computing and Applications, B. Liu, M. Ma, and J. Chang, Eds., Berlin, Heidelberg: Springer, 2012, pp. 246-252. https://doi.org/10.1007/978-3-642-34062-8_32

Z. Zhang, “Introduction to machine learning: k-nearest neighbors,” Ann. Transl. Med., vol. 4, no. 11, p. 218, Jun. 2016. https://doi.org/10.21037/atm.2016.03.37

H. Zhang, and J. Su, “Naive Bayesian Classifiers for Ranking,” in Machine Learning: ECML 2004, J.-F. Boulicaut, F. Esposito, F. Giannotti, and D. Pedreschi, Eds., Berlin, Heidelberg: Springer, 2004, pp. 501-512. https://doi.org/10.1007/978-3-540-30115-8_46

C. Bentéjac, A. Csörgő, and G. Martínez-Muñoz, “A comparative analysis of gradient boosting algorithms”, Artif. Intell. Rev., vol. 54, no. 3, pp. 1937-1967, Mar. 2021. https://doi.org/10.1007/s10462-020-09896-5

N. Kour, S. Gupta, and S. Arora, “Computer-Vision Based Diagnosis of Parkinson’s Disease via Gait: A Survey,” IEEE Access, vol. 7, pp. 156620-156645, Oct. 2019. https://doi.org/10.1109/ACCESS.2019.2949744

A. Landolfi et al., “Machine Learning Approaches in Parkinson’s Disease”, Curr. Med. Chem., vol. 28, no. 32, pp. 6548-6568, Oct. 2021. https://doi.org/10.2174/0929867328999210111211420

Y. Yang, P. Liu, Y. Sun, N. Yu, J. Wu, and J. Han, “A Video-Based Method to Classify Abnormal Gait for Remote Screening of Parkinson’s Disease,” in 2021 40th Chinese Control Conf. (CCC), Shanghai, China, 2021, pp. 3357-3362. https://doi.org/10.23919/CCC52363.2021.9549992

L. Gong, J. Li, M. Yu, M. Zhu, and R. Clifford, “A novel computer vision based gait analysis technique for normal and Parkinson’s gaits classification,” in 2020 IEEE Int. Conf. Dependable Autonomic Secure Computing, Intl Conf on Pervasive Intelligence and Computing, Calgary, AB, Canada, 2020, pp. 209-215. https://doi.org/10.1109/DASC-PICom-CBDCom-CyberSciTech49142.2020.00045

S. Agahian, F. Negin, and C. Köse, “An efficient human action recognition framework with pose-based spatiotemporal features,” Eng. Sci. Technol. Int. J., vol. 23, no. 1, pp. 196-203, Feb. 2020. https://doi.org/10.1016/j.jestch.2019.04.014

S. Niño, J. A. Olmos, J. C. Galvis, and F. Martínez, “Parkinsonian gait patterns quantification from principal geodesic analysis,” Pattern Anal. Appl., vol. 26, no. 2, pp. 679-689, May. 2023. https://doi.org/10.1007/s10044-022-01115-x

E. Balaji, D. Brindha, V. K. Elumalai, and K. Umesh, “Data-driven gait analysis for diagnosis and severity rating of Parkinson’s disease,” Med. Eng. Phys., vol. 91, no. 1, pp. 54-64, May. 2021. https://doi.org/10.1016/j.medengphy.2021.03.005

How to Cite
[1]
J. Portilla, E. Rangel Pieschacon, O. Bacca, P. C. Ramírez, L. Guayacán, and F. Martínez Carrillo, “Correlative Postural Gait Descriptor to Discriminate Parkinsonian Findings in a Markerless Analysis”, TecnoL., vol. 29, no. 65, p. e3432, Feb. 2026.

Downloads

Download data is not yet available.
Published
2026-02-12
Section
Research Papers

Funding data

Crossref Cited-by logo
Article metrics
Abstract views 333
Galley views 286
PDF Views 238
HTML views 15
Other views 33